An airborne particle counter is an advanced measurement instrument used to detect, count, and characterize particles present in the air. These systems are designed for aerosol and particle measurements across a wide range of applications, including environmental research, air quality monitoring, atmospheric research, industrial processes, cleanrooms, occupational health, nanoparticle research, and process control.

In the Airborne Particle Counter category, you can find a wide range of professional systems for measuring particle number concentration, including condensation-based particle counters such as CPC and CNC systems, which are suitable for measuring extremely small particles that cannot be detected directly using conventional optical methods.

The instruments in this category are suitable for research laboratories, universities, research institutes, industrial companies, environmental monitoring organizations, calibration laboratories, equipment manufacturers, and quality control systems.

What Is an Airborne Particle Counter?

An airborne particle counter measures the number of particles present within a defined volume of air. Unlike instruments that measure only particle mass concentration, a particle counter provides information about Particle Number Concentration, meaning the number of particles per unit volume.

This type of measurement is especially important when dealing with very small particles. A large number of ultrafine particles may have a relatively low total mass, while still being highly significant for environmental, industrial, or research applications.

Condensation Particle Counter, CPC

One of the main technologies used in this field is the Condensation Particle Counter, commonly known as a CPC.

CPC instruments are designed to measure extremely small airborne particles. Their operating principle is based on enlarging the particles through a condensation process. Small particles act as condensation nuclei, grow to a size that can be detected optically, and are then counted by the instrument.

This method enables the measurement of particles that are much smaller than those that can be counted directly by a conventional optical particle counter.

The category includes models such as:

  • CPC3007
  • CPC3772
  • CPC3775
  • CPC3783
  • CPC3787
  • CPC3788
  • EEPS/CPC systems and additional particle and aerosol measurement solutions

Different models are designed for different particle size ranges, concentration ranges, flow rates, and applications.

Nanoparticle Measurement in Air

One of the most important applications of CPC particle counters is the measurement of nanoparticles and ultrafine particles.

Particles in the nanometer size range can be generated by many different processes, including combustion, engines, industrial processes, welding, materials research, nanomaterial manufacturing, and chemical processes.

Because these particles are extremely small, conventional particle measurement instruments may not be able to detect them directly. CPC systems solve this problem by enlarging the particles through condensation before counting them.

The ability to measure the numerical concentration of nanoparticles is particularly important in aerosol research, atmospheric science, emissions research, industrial applications, and environmental and health-related studies.

Measuring Airborne Particle Concentration

A particle counter provides a key parameter: the number of particles per unit volume.

This measurement can be used for:

  • Real-time particle monitoring
  • Identifying emission sources
  • Comparing different areas or environments
  • Monitoring industrial processes
  • Evaluating filtration system performance
  • Nanoparticle research
  • Monitoring changes over time
  • Environmental and atmospheric research
  • Quality control in manufacturing processes
  • Aerosol research

When a particle counter is combined with additional particle sizing systems, it is possible to obtain more detailed information about particle size distribution and the characteristics of the airborne particle population.

What Is the Difference Between a Particle Counter and an Aerosol Monitor?

These terms are sometimes used interchangeably, but in practice they can refer to different types of instruments.

A particle counter generally focuses on counting the number of particles present in the air.

An aerosol monitor may measure particle mass concentration, such as PM1, PM2.5, and PM10.

A particle size analyzer is designed to measure the particle size distribution.

It is therefore important to define in advance what needs to be measured: particle number, particle mass, particle size, size distribution, or a combination of these parameters.

Optical Particle Counter vs. CPC Particle Counter

An optical particle counter detects particles by measuring light scattered by individual particles. When a particle passes through the measurement zone, it scatters light, and the instrument detects and classifies it.

A CPC particle counter, on the other hand, is designed to detect much smaller particles. Before counting them optically, the instrument enlarges the particles through condensation.

For this reason, CPC systems are particularly suitable for applications involving ultrafine particles and nanoparticles.

Applications of Airborne Particle Counters

Airborne particle counters are used across a wide range of fields.

Aerosol Research

Aerosol research requires accurate measurements of how particles are generated, transformed, and dispersed in the air. CPC systems are key instruments in this field, particularly for measurements in the nanometer size range.

Atmospheric Research

Atmospheric particles play an important role in environmental and climate-related processes. Measuring particle number concentration enables researchers to study new particle formation, air pollution, and different emission sources.

Industrial Applications

In industrial environments, particle counters can be used for emission monitoring, quality control, filtration system evaluation, and tracking particles generated during manufacturing processes.

Occupational Health

Certain workplaces can generate very small airborne particles as a result of welding, cutting, grinding, combustion, or handling nanomaterials.

A particle counter can help identify changes in particle levels and compare exposure conditions during different work processes.

Filtration System Testing

Particle counters can be used to measure particle concentration before and after a filter. Comparing these values helps evaluate filtration efficiency and system performance.

Vehicle and Engine Emissions Research

CPC systems are also widely used in engine, combustion, and emissions research. They can measure the number of particles generated during a process and enable comparisons between different fuels, engine technologies, and emission control systems.

Portable Particle Counters

Some applications require measurements in the field rather than in a laboratory.

A portable particle counter can be used for:

  • Environmental measurements
  • Industrial monitoring
  • Workplace assessments
  • Comparing different locations
  • Identifying emission sources
  • Temporary monitoring
  • Field research

A model such as the CPC3007 is designed for portable applications and enables particle concentration measurements where a compact and mobile solution is required.

How to Choose an Airborne Particle Counter

Selecting the right instrument depends on several important parameters.

The first consideration is the minimum particle size that needs to be measured. If nanoparticles or ultrafine particles are the main target, a CPC may be required.

The expected particle concentration range should also be considered. Some applications involve extremely low particle concentrations, while others require measurements at significantly higher concentrations.

Other important selection criteria include:

  • Particle size range
  • Particle concentration range
  • Sampling flow rate
  • Response time
  • Portability
  • Data logging capabilities
  • Computer connectivity
  • Environmental operating conditions
  • Condensation fluid or measurement technology
  • Compatibility with existing measurement systems
  • Calibration and maintenance requirements

What Is the Difference Between Different CPC Particle Counter Models?

Not all CPC particle counters are designed for the same application.

Different models may vary in the minimum detectable particle size, concentration range, flow rate, response speed, operating principle, and integration capabilities.

For example, an advanced laboratory research system may require particularly high sensitivity, while a field application may prioritize portability and ease of use.

The correct model should therefore be selected according to the specific measurement objective rather than only according to the overall measurement range.

Professional Solutions for Airborne Particle Counting

Meteo-Tech offers a range of professional solutions for airborne particle measurement, particle counting, nanoparticle measurement, and aerosol research, including advanced CPC systems and particle counters.

These instruments are suitable for applications in aerosol research, air quality monitoring, environmental science, industrial processes, emissions monitoring, occupational health, and atmospheric research.

Selecting the appropriate particle counting system enables users to accurately measure particle concentration, identify real-time changes, compare different conditions, and obtain reliable data for research, development, monitoring, and quality control.